Parameter Setups Files |
Up to500 files stored instrument parameter setups. |
A-Scan Files |
Up to 500files including operation parameters plus A-scan, the stored datasets can be easily previewed, recalled and exported to a computer for edit and printing. |
Thickness Files |
Up to 10,000 thickness values stored in single thickness file. |
PC Communication |
Bi-directional RS232-USB adaptor connected with PC. |
DAC/ TCG |
DAC or TCG with a maximum of 16 reference echoes, 4 other curves can be displayed with variable dB intervals. DAC curves can be varied with variable dB or variable range. |
AVG/DGS |
DGS curves can be displayed automatically; DGS curves can be varied with variable dB or variable range. |
Readings |
Up to selectable 26 readings (Sound path, projection distance, depth, echo height, and ERS.) |
B-Scan |
Selectable corrosion-featured B-scan and full-featured B-scan |
Square Wave Pulser |
Square wave pulsers allow optimum probe matching by adjusting pulse width and voltage. Difficult to penetrate metallic applications and especially non- metals inspection like composite materials are optimized. Pulse width is tunable up to 1000 ns in 10 ns steps. Pulser voltage is adjustable from 20 to 500 V in 10 V steps. |
Rectification |
Positive half-wave, negative half-wave, full-wave, RF |
Reject (suppression) |
0 to 90% linear |
Units |
Inch, millimeter, or microsecond selectable |
Languages |
Selectable English, Chinese |
Gate Monitors |
Two independent flaw gates controllable over entire sweep range |
Measurement Modes |
Zero-to-first, multi-echo with selectable flank or peak detection |
TTL Output |
Three independently assignable outputs, instantaneous, timed, latched with visual LED and audible horn alarms |
Alarm |
Selectable positive logic, negative logic, upper limit thickness or lower limit thickness alarm mode |
Curved surface correction |
Corrects sound path information when using an angle beam transducer to circumferentially inspect a curved surface for either tubular or bar inspections. |
Auto Calibration |
Measurement and setting of sound velocity and probe delay using two known calibration echoes (2-point calibration) |
Auto Gain |
Adjust automatically the system sensitivity to bring (increase or decrease) the measured echo to the suitable echo height. Echo height setting value from 10 % to 90 % of the screen height. |
Display Screen |
5.7 inch LED backlight TFT_LCD, display resolution 320 x 240 pixels, selectable 4 scheme colors and 8 A Scan colors. |
A-Scan Resolution |
Standard 200 x 220 pixels, or 100 x 220 pixels |
Display Update Rate |
160Hz |